Problem Statement
A Nortel CS1000 (CS1K) device reports a Major ITG2003 alarm with Alarm Code ACT and a file I/O error indicating "No space left on device" while opening or writing an OM high-water-mark file.
Impact
The affected CS1000 component may be unable to write operational measurement, log, or alarm-related files. CPU status may remain normal while the alarm persists because the triggering condition is storage-related rather than CPU-related.
Alarm
Major alarm: Nortel CS1000 (CS1K), Maint Object ITG2003, Alarm Code ACT, fileError/File IO error, OM_HighWaterMark file, "No space left on device"
Troubleshooting Steps
- Confirm the alarm in the monitoring dashboard and record the device type, alarm severity, maint object ITG2003, Alarm Code ACT, and the file I/O error text.
- Verify overall system health. Check that CPUs are normal and look for any additional active alarms that may indicate a broader platform issue.
- Access the affected CS1000 or associated management/server component using the approved support method.
- Check filesystem capacity and inode usage with standard platform commands such as `df -h` and `df -i`. Focus on the filesystem that contains the referenced Nortel/SPS/OM file location if visible.
- Identify large or rapidly growing files with commands such as `du -sh <directory>` and review log, OM, archive, or temporary directories according to local maintenance procedures.
- Do not delete active application files. If space must be reclaimed, remove or archive only files confirmed to be safe by the site runbook, vendor guidance, or the responsible voice/platform team.
- After reclaiming space, confirm the filesystem is no longer full and that there is sufficient free capacity and inode availability.
- Monitor the CS1000 alarm dashboard to confirm the ITG2003 Major alarm clears or changes state.
- If the alarm remains active after storage is available, restart only the approved affected service or escalate to the CS1000/vendor support team for file-system or application-level recovery.
- Document the storage condition found, actions taken, current CPU status, and final alarm state.
Resolution
Free or restore capacity on the filesystem referenced by the CS1000 ITG2003 file I/O error, then verify that the device can write the OM high-water-mark file and that the Major alarm clears. If disk space is available but the alarm persists, escalate for CS1000 application or filesystem recovery.